Discharge History

FY2023 Sea Area Monitoring Results
(concentrations of tritium in seawater)

Tritium concentrations obtained sea area monitoring within a 3 km of the power station are well below our operational index (discharge suspension level: 700 Bq/L).
[Click here for details of operational indices]

Results of quick tritium measurement*
Round Within a 3 km of the power station Within a 10 km square
in front of the power station
1st Max. 10 Bq/liter Below the detection limit
2nd Max. 22 Bq/liter Below the detection limit
3rd Max. 11 Bq/liter Below the detection limit
4th Max. 16 Bq/liter Below the detection limit

*Measurement performed with a detection limit of approx. 10 Bq/liter in order to obtain the results quickly.

Comparison of concentration of tritium in seawater

*1: This standard has been stipulated based on the calculation that if a person were to drink approximately 2 L of the water coming out of the discharge outlet of a nuclear facility every day for one year, his/her exposure would be 1 mSv.

*2: Source: Environmental Radioactivity and Radiation in Japan (Period: April 2019 to March 2022)

*3: Alternative location if safety cannot be ensured at T-2

FY 2023 Discharge History

(as of Mar. 17, 2024)

Annual accumulated ALPS treated water discharge volume

00,000 ㎥

Total accumulated ALPS treated water
discharge volume since the commencement
of discharge in August 24, 2023:
00,000,000

Annual accumulated tritium discharge volume

Approx. 0 TBq

There may be slight differences between planned and
actual values due to factors such as differences in
analysis results between the transfer source tanks and
the measurement/confirmation tanks.


Total accumulated tritium discharge volume
since the commencement of discharge
in August 24, 2023:
Approx. 00 TBq

Annual discharge limit of tritium:
22 TBq

Discharge history for each discharge

Analysis results of ALPS treated water prior to dilution ALPS treated water discharge history
Round Analysis date
at the
measurement/
confirmation facility*1
Tritium
concentration
The sum of the ratios of the concentration of each radionucide to the regulatory concentration,
excluding tritium
Discharge period Tritium concentrations after dilution*2 Amount of ALPS treated water Amount of tritium*3
1st Jun. 22, 2023 14×104
Bq/liter
0.28
<
Regulatory standards
1
Aug. 24, 2023
~
Sep. 11, 2023
Max. 220 Bq/liter 7,788 ㎥ Approx. 1.1 TBq
2nd Sep. 21, 2023 14×104
Bq/liter
0.25
<
Regulatory standards
1
Oct. 5, 2023
~
Oct. 23, 2023
Max. 189 Bq/liter 7,810 ㎥ Approx. 1.1 TBq
3rd Oct. 19, 2023 13×104
Bq/liter
0.25
<
Regulatory standards
1
Nov. 2, 2023
~
Nov. 20, 2023
Max. 200 Bq/liter 7,753 ㎥ Approx. 1.0 TBq
4th Feb. 26, 2024 17×104
Bq/liter
0.34
<
Regulatory standards
1
Feb. 28, 2024
~
Mar. 17, 2024
Max. 254 Bq/liter 7,794 ㎥ Approx. 1.3 TBq
num mm. dd
20yy
n万
Bq/liter
0.55
<
Regulatory standards
1
mm. 2, 2023
~
mm. 2, 2023
Max. n Bq/liter 0㎥ Approx. 0 T Bq

*1 Click on the date of analysis to see the pre-discharge analysis results of ALPS treated water in the Measurement /Confirmation tanks.

*2 During the discharge period, the tritium concentration in samples taken from seawater pipes is analyzed daily. Each result is given as "○○±△△Bq/L" taking into account the uncertainty (accuracy of the analysis data), and the value where "○○+△△Bq/L" reaches the maximum among the results during the period is given as "Maximum ▲▲Bq/L".

*3 There may be slight differences between planned and actual values due to factors such as differences in analysis results between the transfer source tanks and the measurement/confirmation tanks.

FY 2023 Discharge Plan

ALPS treated water is discharged starting from which stored in the measurement/confirmation facility.

Round Discharge period Amount of
ALPS treated water
Tritium concentration*1 Amount of tritium*3
1st Aug. 2023 Approx. 7,800 ㎥ 14×104 Bq/liter*2 Approx. 1.1
TBq
2nd Oct. 2023 Approx. 7,800 ㎥ 14×104 Bq/liter*2 Approx. 1.1
TBq
3rd Nov. 2023 Approx. 7,800 ㎥ 13×104 Bq/liter*2 Approx. 1.0
TBq
4th Feb. 2024 Approx. 7,800 ㎥ 17×104~21×104 Bq/liter*2 Approx. 1.4
TBq

*1 Tritium concentrations will be less than 1,500 Bq/liter by dilution more than 700 times with seawater

*2 Average value of the tank group that was assessed taking into account the radioactive decay until July 1, 2023

*3 There may be slight differences between planned and actual values due to factors such as differences in analysis results between the transfer source tanks and the measurement/confirmation tanks.